July 5 (Reuters) - Grupa Azoty Zakłady Chemiczne Police SA
PCE.WA
* SAID ON THURSDAY THAT DURING PLANNED REPAIR STANDSTILL AT
ITS
NITRO BUSINESS UNIT CONDUCTED BETWEEN APRIL 4 AND JUNE 6 A
BOILER DEFECT WAS DETECTED AT THE INSTALLATION OF SYNTHESIS GAS
PREPARATION
* AS A RESULT OF DETECTING THE DEFECT, THE INSTALLATION OF
THE
AMMONIA SYNTHESIS AND UREA SYNTHESIS WAS TEMPORARILY SHUT DOWN
STARTING FROM MAY 6, 2019
* DAMAGE CAUSED BY DISCONTINUITIES IN WELDED CONNECTIONS OF
BOILERS, RESULTS IN THE TOTAL OUTAGE OF UREA PRODUCTION UNTIL
AUG. 11, 2019
* THE DEFECT HAS NO NEGATIVE IMPACT ON THE ENVIRONMENT
* ESTIMATED FINANCIAL IMPLICATIONS OF THE TEMPORARY SHUTDOWN
OF
THE INSTALLATION CAUSED BY THE DEFECT WILL BE ANNOUNCED LATER
Source text for Eikon: urn:newsml:reuters.com:*:nEMbgpWt7a
Further company coverage: PCE.WA
(Gdynia Newsroom)
((gdynia.newsroom@thomsonreuters.com; +48 58 772 0920))